Monitoring: node_exporter + vmagent dual-write on each host (flakes-c6gm)
Metrics agent on every monitored host, dual-writing to all hubs.
Spec
services.prometheus.exporters.node: enablesystemdcollector (unit active/failed state) plus defaults (cpu, mem, fs, net, hwmon, pressure). Listen on localhost only.services.vmagent: scrape local node_exporter (and VM/VL self-metrics on hubs);remoteWrite.url= first hub, remaining hubs viaextraArgs-remoteWrite.url=...(nixpkgs module only takes one URL). Set-remoteWrite.tmpDataPathunder the state dir so per-URL queues persist across restarts / link outages; set a sane-remoteWrite.maxDiskUsagePerURL.- External labels:
host,site(from shared module). - Optional extra: smartctl exporter for disks (could be a follow-up).
Todo
- node_exporter with systemd collector
- vmagent with all hub URLs + persistent queue
- Verify both hubs see
up{host="pc"}andup{host="edger"} - Verify buffering — verified naturally: pc vmagent queued for edger ~30 min before edger hub existed; after edger came up it holds pc node samples from 14:28Z continuously (34 x 1m, no gap), queues drained to 0.
Notes
- 2026-10-07: pc switched (mixins/nixos/services/monitoring/agent.nix). pc hub has up{host=“pc”} for node/vmagent/victoriametrics/victorialogs, 870 node_systemd_unit_state series. Already surfaced: greetd.service failed on pc.
- instance relabelled to hostname (scrape address is 127.0.0.1 on every host). external_labels host/site from monitoring.labels.
- Queue to edger retrying until edger’s hub is deployed.
Summary of Changes
mixins/nixos/services/monitoring/agent.nix: node_exporter (systemd, processes collectors) and vmagent bound to localhost; vmagent writes to every hub URL with per-URL on-disk queues (1GB cap each), external labels host/site, instance relabelled to hostname. Hubs also scrape their own VM/VL.- Deployed and verified on pc and edger: both hubs show 5 targets up per host.